SITOP smart 120 W stabilized power supply input: 120/230 V AC output: 24 V DC/5 A version with PFC
 
Input
type of the power supply network1-phase AC
supply voltage at AC 
● initial valueSet by means of selector switch on the device
supply voltage 
● 1 at AC rated value120 V
● 2 at AC rated value230 V
input voltage 
● 1 at AC85 ... 132 V
● 2 at AC170 ... 264 V
design of input wide range inputNo
overvoltage overload capability2.3 × Vin rated, 1.3 ms
operating condition of the mains bufferingat Vin = 93/187 V
buffering time for rated value of the output current in the event of power failure minimum20 ms
operating condition of the mains bufferingat Vin = 93/187 V
line frequency 
● 1 rated value50 Hz
● 2 rated value60 Hz
line frequency47 ... 63 Hz
input current 
● at rated input voltage 120 V2.1 A
● at rated input voltage 230 V1.15 A
current limitation of inrush current at 25 °C maximum32 A
duration of inrush current limiting at 25 °C 
● typical3 ms
I2t value maximum0.8 A²·s
fuse protection typeT 3,15 A/250 V (not accessible)
● in the feederRecommended miniature circuit breaker: from 6 A characteristic C
Output
voltage curve at outputControlled, isolated DC voltage
output voltage at DC rated value24 V
output voltage 
● at output 1 at DC rated value24 V
relative overall tolerance of the voltage3 %
relative control precision of the output voltage 
● on slow fluctuation of input voltage0.1 %
● on slow fluctuation of ohm loading0.5 %
residual ripple 
● maximum150 mV
● typical50 mV
voltage peak 
● maximum240 mV
● typical150 mV
adjustable output voltage22.8 ... 28 V
product function output voltage adjustableYes
type of output voltage settingvia potentiometer
display version for normal operationGreen LED for 24 V OK
behavior of the output voltage when switching onOvershoot of Vout approx. 4 %
response delay maximum0.1 s
voltage increase time of the output voltage 
● typical50 ms
output current 
● rated value5 A
● rated range0 ... 6 A; 6 A up to +45 °C
supplied active power typical144 W
short-term overload current 
● on short-circuiting during the start-up typical17 A
● at short-circuit during operation typical17 A
duration of overloading capability for excess current 
● on short-circuiting during the start-up100 ms
● at short-circuit during operation200 ms
product feature 
● bridging of equipmentYes
number of parallel-switched equipment resources for increasing the power2
Efficiency
efficiency in percent87 %
power loss [W] 
● at rated output voltage for rated value of the output current typical17 W
Closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical0.3 %
relative control precision of the output voltage load step of resistive load 50/100/50 % typical1 %
setting time 
● load step 50 to 100% typical0.2 ms
● load step 100 to 50% typical0.2 ms
Protection and monitoring
design of the overvoltage protection< 33 V
response value current limitation6.4 ... 6.6 A
property of the output short-circuit proofYes
design of short-circuit protectionConstant current characteristic
enduring short circuit current RMS value 
● typical10 A
display version for overload and short circuit-
Safety
galvanic isolation between input and outputYes
galvanic isolationSafety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection classClass I
leakage current 
● maximum3.5 mA
● typical0.4 mA
protection class IPIP20
Approvals
certificate of suitability 
● CE markingYes
● UL approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604)
● CSA approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1, UL 1604)
● cCSAus, Class 1, Division 2No
● ATEXNo
certificate of suitability 
● IECExNo
● NEC Class 2No
● ULhazloc approvalNo
● FM registrationNo
type of certification CB-certificateYes
certificate of suitability 
● EAC approvalYes
certificate of suitability shipbuilding approvalYes
shipbuilding approvalABS, GL
Marine classification association 
● American Bureau of Shipping Europe Ltd. (ABS)Yes
● French marine classification society (BV)No
● DNV GLYes
● Lloyds Register of Shipping (LRS)No
● Nippon Kaiji Kyokai (NK)No
EMC
standard 
● for emitted interferenceEN 55022 Class B
● for mains harmonics limitationEN 61000-3-2
● for interference immunityEN 61000-6-2
environmental conditions
ambient temperature 
● during operation0 ... 60 °C; with natural convection
● during transport-40 ... +85 °C
● during storage-40 ... +85 °C
environmental category according to IEC 60721Climate class 3K3, 5 … 95% no condensation
Mechanics
type of electrical connectionscrew-type terminals
● at inputL, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
● at outputL+, M: 2 screw terminals each for 0.5 ... 2.5 mm²
● for auxiliary contacts-
width of the enclosure50 mm
height of the enclosure125 mm
depth of the enclosure125 mm
required spacing 
● top50 mm
● bottom50 mm
● left0 mm
● right0 mm
net weight0.5 kg
product feature of the enclosure housing can be lined upYes
fastening methodSnaps onto DIN rail EN 60715 35x7.5/15
MTBF at 40 °C1 694 714 h
other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)